Broseley eVolution 7 Insert Provozní pokyny

Procházejte online nebo si stáhněte Provozní pokyny pro Sporáky Broseley eVolution 7 Insert. Broseley eVolution 7 Insert Operating instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 30
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation & Operating
Instructions
Covering Models:
eVolution 4 & 7 Insert
Wood Burning Stoves
Tested to EN 13229
These appliances must be installed and commissioned by a HETAS registered engineer
MS11-11 Issue 3 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - Instructions

Installation & Operating InstructionsCovering Models: eVolution 4 & 7 InsertWood Burning Stoves Tested to EN 13229These appliances

Strany 2 - Contents

AssemblySmoke Exempt modification. Evolution 4With both the Evolution 4 & 7 when it comes to installations in smoke control areas, you will nee

Strany 3 - Packing List

AssemblyLiner ConnectionUnbolt the flue spigot from the stove (done by removing the internal baffle to access the fixings). Connect and seal the 150m

Strany 4 - Health & Safety

AssemblyWith both the Evolution 4 & 7 insert stoves, several fixing points are provided for ease of installation. The fixing points will come se

Strany 5 - Specifications

AssemblyThe images below detail the sequence for installing the internal firebricks in the eVolution 41. Ensure there is no ash are debris to prevent

Strany 6 - Dimensions

AssemblyThe images below detail the sequence for installing the internal firebricks in the eVolution 71. Ensure that the firebox is clear of anything

Strany 7

Controls LayoutThe diagram below shows the position of the air controls, these controls need to be operated correctly to control the combustion rate

Strany 8 - Chimney Requirements

Controls ExplainedFire needs air to burn therefore the stove is fitted with air controls that allow you to regulate the amount of combustion air ther

Strany 9 - Combustion Air Requirements

Recommended FuelsThe HETAS Ltd. appliance approval along with approval in a smoke controlled area only covers the use of the following fuels in this

Strany 10 - Assembly

Lighting the StoveCuringOn initial firing you will notice a very pungent odour, this is caused through the curing of the paint, we recommend starting

Strany 11

Burning WoodOnce you have kindled your stove (see previous page) and your chimney (flue) is sufficiently heated and a large base of burning embers is

Strany 12

ContentsIntroduction 3Packing List 3Health & Safety 4Specifications 5Dimensions 6Hearth Requirements & Clearances 7Chimney Requirements 8Comb

Strany 13

Smoke Exempt RequirementsThe Clean Air Act 1993 and Smoke Control AreasUnder the Clean Air Act local authorities may declare the whole or part of the

Strany 14

Smoke Exempt RequirementseVo 7 Inset - IgnitionThe procedure adopted for ignition is to build a bed of embers in stages with the objective of warmin

Strany 15 - Controls Layout

Smoke Exempt RequirementsFURTHER REQUIREMENTS:1. It is important to follow these instructions in order to achieve clean burning and to maximise the

Strany 16 - Controls Explained

Warning NotesOver-FiringIt is extremely important that you do NOT leave the air control in the fully open position for extended periods or run the ap

Strany 17 - Recommended Fuels

MaintenanceAsh RemovalThe ash pan can be removed by using the ash tool to hook out the grate so that you can grasp the pan using the gloves provided.

Strany 18 - Lighting the Stove

Trouble-shootingSmoke comes out of the stove when the loading door is opened.• The chimney cavity into which the 150mm flue pipe has been installed m

Strany 19 - Burning Wood

Commissioning FormCommissioning Statement and Check-listStove Purchased From:_____________________________________________________Address:___________

Strany 20 - Smoke Exempt Requirements

EC DeclarationDECLARATION OF CONFORMITYACCORDING TO DIRECTIVES 89/106/EEC (CONSTRUCTION PRODUCTS) BROSELEY FIRES LTD KNIGHTS WAY, BATTLEFIELD ENT

Strany 21

EC DeclarationDECLARATION OF CONFORMITYACCORDING TO DIRECTIVES 89/106/EEC (CONSTRUCTION PRODUCTS) BROSELEY FIRES LTD KNIGHTS WAY, BATTLEFIELD ENT

Strany 22

Annual Service Record1ST YEAR SERVICE completion date:

Strany 23 - Warning Notes

IntroductionMay we take this opportunity to thank you for choosing one of our stoves. These appliances are designed to burn wood logs and wood derive

Strany 24 - Maintenance

WarrantyThis appliance must be installed and commissioned by a fully qualified, registered engineer. A “Declaration of completion Certificate” must b

Strany 25 - Trouble-shooting

Health & SafetySpecial care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met.Insta

Strany 26 - Commissioning Form

SpecificationsIn the UK these stoves have been approved by HETAS Ltd as intermittent heating appliances for burning manufactured or naturally occurri

Strany 27 - EC Declaration

DimensionsAll dimensions are in millimetresEvolution 4Evolution 7MS11-11 Issue 3 6

Strany 28

Hearth Requirements & ClearancesYour stove must be installed on a solid, level non combustible hearth. The hearth does not need to be constru

Strany 29 - Annual Service Record

Chimney Requirements This appliance must not be fitted into a chimney serving another heating appliance. It is most important that there is no obstru

Strany 30 - Warranty

Combustion Air RequirementsIn order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the

Komentáře k této Příručce

Žádné komentáře